| Page 95 | American University of Sharjah

Metal Laser Sintering System

300W laser, 0.02–0.03 mm layers, Ar/N2 protection

Manufacturer / Vendor: 
Farsoon Technologies (3D printer)
Model: 
FS121M-E
Building: 
Room Number: 
0002
Functionality: 
Metal 3D printing: prototypes, tools, dental, jewelry
Custodian Department / Unit: 
Materials Research Center
Point of Contact Name: 
N/A
Status: 

RF Sputtering System

DC/RF sputter, 1–2 inch targets, high vacuum, substrate rotation

Manufacturer / Vendor: 
Seren RF Source
Model: 
N/A
Building: 
Room Number: 
0001
Functionality: 
Thin film deposition, metal/oxide coatings, device fabrication
Custodian Department / Unit: 
Materials Research Center
Point of Contact Name: 
Dr. Muhammed Razi Paleth
Point of Contact Email: 
Status: 

Cyclic Voltammetry

±10V, ±250 mA, 1 MHz bandwidth, multiple electrode configs

Manufacturer / Vendor: 
CH Instruments
Model: 
660
Building: 
Room Number: 
0002
Functionality: 
Electrochemical research: sensors, batteries, electrocatalysis, corrosion
Custodian Department / Unit: 
Materials Research Center
Point of Contact Name: 
Dr. Maduraiveeran Govindhan
Point of Contact Email: 
Status: 

Wire Bonder

Semi-auto/manual, supports Al, Au, Cu wires (17–75 µm)

Manufacturer / Vendor: 
MP iBond5000 w/ Olympus microscope
Model: 
iBond5000
Building: 
Room Number: 
0002
Functionality: 
Wire bonding for microdevices and physical property measurement
Custodian Department / Unit: 
Materials Research Center
Point of Contact Name: 
Dr. Muhammed Razi Paleth
Point of Contact Email: 
Status: 

Solar Simulator

0.2–1 Sun irradiance, AM0 spectrum, temp monitoring

Manufacturer / Vendor: 
Sciencetech
Model: 
N/A
Building: 
Room Number: 
0002
Functionality: 
Simulates sunlight for testing photovoltaics, materials, aerospace
Custodian Department / Unit: 
Materials Research Center
Point of Contact Name: 
Dr. Manoj Mohan
Point of Contact Email: 
Status: 

UV-VIS Spectrophotometer

Stability ≤ 6%; detection limit ≤ 0.03 ppb

Manufacturer / Vendor: 
Shimadzu
Model: 
UV-2700i
Building: 
Room Number: 
0235
Functionality: 
UV-visible absorbance for quantitative analysis
Custodian Department / Unit: 
Chemistry
Point of Contact Name: 
Dr. Thomas Job
Point of Contact Email: 
Status: 

Atomic Absorption Spectrometer (Flame & Graphite)

≤±0.30 nm wavelength accuracy; Detection limit ≤ 0.006 ppm

Manufacturer / Vendor: 
Shimadzu
Model: 
AA-7000
Building: 
Room Number: 
0201
Functionality: 
Metal/metalloid quantification in samples
Custodian Department / Unit: 
Chemistry
Point of Contact Name: 
Dr. Thomas Job
Point of Contact Email: 
Status: 

Spectrofluorophotometer

150 W Xenon lamp; 250–900 nm; ≤1.0 nm resolution; Raman S/N > 1000 RMS

Manufacturer / Vendor: 
Shimadzu
Model: 
RF-6000
Building: 
Room Number: 
0235
Functionality: 
Study of compound concentration and fluorescence properties
Custodian Department / Unit: 
Chemistry
Point of Contact Name: 
Dr. Thomas Job
Point of Contact Email: 
Status: 

Spray Pyrolysis

Max 550°C, X–Y spray motion, programmable dispensing

Manufacturer / Vendor: 
Holmarc
Model: 
HO-TH-04BT
Building: 
Room Number: 
0002
Functionality: 
Thin film deposition for solar cell research
Custodian Department / Unit: 
Materials Research Center
Point of Contact Name: 
Dr. Manoj Mohan
Point of Contact Email: 
Status: 

Benchtop Nuclear Magnetic Resonance Spectrometer

100 MHz 1H/13C; 1D, T1, T2, COSY, TOCSY, JRES, HSQC, HMBC, NOESY, ROESY; solvent suppression; graphical pulse programming

Manufacturer / Vendor: 
Nanalysis
Model: 
100PRO
Building: 
Room Number: 
0201
Functionality: 
Structure elucidation and kinetics of samples
Custodian Department / Unit: 
Chemistry
Point of Contact Name: 
Dr. Thomas Job
Point of Contact Email: 
Status: 

Pages

You are now leaving the American University of Sharjah website.

By continuing, you will be taken to a website not affiliated with American University of Sharjah. Links to external sites are provided only for users' convenience and imply no endorsement of the site and/or its content. Note that the privacy policy and security settings of the linked site may differ from those of the AUS website.